Docs

Warm & Happy Starts Here!

Get help straight from the team at Enchanted Fireside.

Quadra-Fire Trekker: What the Lights Mean

Indicators and Lights

Quadra-Fire Trekker: What the Lights Mean

LED color and blink codes for the Quadra-Fire Trekker pellet stove and insert, and what each one means.

Last updated on 05 Oct, 2026

< Back to descriptions of all lights

The Quadra-Fire Trekker pellet stove and insert use one indicator light that changes color and blink pattern to show what the stove is doing. Count the number of flashes between pauses (flashes are per one second unless noted), then find the color and count below.

LED Color

Flashes between pauses

What it means

Notes

Green

Steady ON while priming the feed tube (max. 2 minutes)

Feed motor is running continuously (priming the feed tube).

When priming the feed system and filling the fire pot, DO NOT OVERFILL the fire pot for ignition. The appliance will automatically go into start-up following the prime function.

Green

1x every 2 seconds

Appliance is on standby.

To start the appliance, follow the start-up sequence.

Green

Blinks continuously

Appliance is in the start-up/ignition sequence.

Green

1x

Stage 1: Low heat

BTU range 14,620 – 19,694 (average 19,054)

Green

2x

Stage 2: Med-Low heat

BTU range 22,102 – 23,506 (average 22,735)

Green

3x

Stage 3: Med heat

BTU range 30,778 – 32,680 (average 31,603)

Green

4x

Stage 4: Med-Hi heat

BTU range 38,576 – 42,914 (average 40,665)

Green

5x

Stage 5: Hi heat

BTU range 49,830 – 52,460 (average 51,528)

Amber

Blinks continuously

Appliance is in the shutdown sequence.

During shutdown, the blowers will shut off when the exhaust temperature has cooled.

Red

1x

Empty Hopper Alarm

This alarm is caused by the fire going out from lack of fuel. Reset by turning the dial to "OFF", then turn the dial to the desired setting.

Red

2x

Exhaust Probe Alarm

Failed component error. See the troubleshooting section of your owner's manual for more information.

Red

4x

Missed Ignition

There are a total of 2 tries per ignition sequence. If after 2 tries there is no rise in exhaust temperature, this error will occur. See the troubleshooting section of your owner's manual for more information.

Red

6x

Encoder Alarm

Failed component error: exhaust speed sensor. See the troubleshooting section of your owner's manual for more information.

Red

8x

Exhaust Over Temperature Alarm

See the troubleshooting section of your owner's manual for more information.